Browsing by Author "Cong, Lin"
Now showing 1 - 2 of 2
- Results Per Page
- Sort Options
Item A High-Efficiency Low-Profile Zero-Voltage Transition Synchronous Non-Inverting Buck-Boost Converter with Auxiliary-Component Sharing(IEEE, 2018-08-16) Cong, Lin; Liu, Jin; Lee, Hoi; Cong, Lin; Liu, Jin; Le, Hoi; 0000-0003-1945-6887 (Lee, H); Cong, Lin; Liu, Jin; Lee, HoiThis paper presents an efficiency-enhanced low-profile zero-voltage-transition (ZVT) synchronous non-inverting buck-boost converter for 48-V tens-of-Watt output applications. By only using three auxiliary components shared between two switching nodes, zero-voltage switching (ZVS) of all four power switches and zero-current switching of the auxiliary switch are achieved in the proposed converter to minimize the switching power loss. Compared with the existing ZVT topologies, the proposed converter reduces the required number of auxiliary components, thereby decreasing the converter volume and power loss. In addition, the proposed converter can be configured into the buck mode with full ZVS capability to support a wide input range from 36 V to 90 V. Experimental results show that the proposed converter can operate at 1 MHz and deliver a maximum output power of 75 W. The measured peak power efficiencies achieve 92.5% and 96.3% in the buck-boost mode and buck mode, respectively. Compared with the state-of-the-art ZVS-based buck-boost counterpart, the proposed converter reduces the volume of the auxiliary circuit by similar to 2 times even with 28% increase in the maximum load current and two times reduction in the switching frequency, and provides higher peak power efficiencies in both buck-boost and buck modes.Item Design Techniques for Volume-Efficient Soft-Switched Power Converters with Enhanced Power Efficiency and Reliability(2020-10-06) Cong, Lin; Lee, HoiZero voltage switching technique has been popular in high voltage DC-DC converter design to increase the switching frequency while maintaining high power efficiency and thus reducing the volume of passive components. Recently, enhancement-mode GaN FETs attracts more and more attention in high voltage converters for better figure of merits in RDSON and QG compared with the traditional MOSFETs. Although GaN FETs have been used in soft-switched DC-DC converters to further improve the power efficiency and power density, GaN FETs can cause more power loss in the third quadrant conduction than traditional MOSFETs if the dead time is not precisely controlled. In addition, fast transition of GaN FETs requires the high-voltage level shifter handle much faster dv/dt without creating logic errors. This dissertation develops a novel GaN driver with adaptive dead time control scheme, based on an innovative methodology of slope-sensing ZVS detection to minimize the third quadrant conduction time of GaN FETs. Also, a differential-mode noise blanking scheme is proposed to increase the dv/dt noise immunity of the high voltage level shifter. The proposed GaN driver can help to reduce power loss by 1.6W and achieve 90.2% power efficiency at 150V input and 2MHz frequency, or 88.6% power efficiency at 400V input and 1MHz frequency. Traditional non-isolated ZVS converters utilize an auxiliary branch to assist soft-switching operation of the active FET. In multiphase topologies or non-inverting buck-boost topology, each active power FET requires an auxiliary branch such that the total number and volume of auxiliary components make the traditional ZVS scheme infeasible. This dissertation proposes a new passive-saving technique to share one auxiliary branch between two active FETs such that the total number and volume of auxiliary components can be reduced by 50%. It is worth to notice that the proposed passive-saving technique can be applied to both ZVS and ZVT topologies. Traditional ZVT converters adopted fixed on-time of the auxiliary switch for simplicity. Since the auxiliary current ripple cannot scale with the load current, power efficiency at light load condition is quite limited. This dissertation proposes a monolithic control loop to regulate the auxiliary current ripple according to load current. Compared with the traditional ZVT converters, the proposed converter with auxiliary current control scheme can improve light load efficiency by 14.5% without folding back switching frequency.